Remove/Replace HVAC (RTU)
ID: W50S8N25QA010Type: Solicitation
Overview

Buyer

DEPT OF DEFENSEDEPT OF THE ARMYW7NR USPFO ACTIVITY NYANG 174SYRACUSE, NY, 13211-7099, USA

NAICS

Plumbing, Heating, and Air-Conditioning Contractors (238220)

PSC

INSTALLATION OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT (N045)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)
Timeline
    Description

    The Department of Defense, specifically the Department of the Army, is soliciting bids for the removal and replacement of the HVAC rooftop unit (RTU) at Building 642, located at Hancock Field in Syracuse, New York. The project requires contractors to provide all necessary labor, materials, tools, and project management to complete the replacement, including the demolition and disposal of the existing unit, and installation of a new 15-ton Trane RTU that complies with current environmental standards. This initiative is part of the government's efforts to enhance infrastructure efficiency and environmental compliance, particularly addressing the replacement of outdated systems that utilize harmful refrigerants. Interested contractors must submit their quotes by 2:00 PM Eastern on November 26, 2024, and are encouraged to attend a site visit on November 12, 2024, at 9:00 AM, with prior registration required. For further inquiries, contact Briana McCaffery at briana.mccaffery@us.af.mil or Richard M. Peirson at richard.peirson@us.af.mil.

    Point(s) of Contact
    Files
    Title
    Posted
    The document outlines a federal government Request for Proposals (RFP) aimed at soliciting applications for federal grants specifically targeting public health initiatives. The primary purpose is to fund innovative programs that address health disparities across vulnerable populations. The RFP emphasizes collaboration among state and local health departments, community organizations, and educational institutions to enhance health outcomes. Key components include eligibility criteria for applicants, funding parameters, application deadlines, and reporting requirements post-award. The document underscores the federal government's commitment to promoting health equity and providing resources for effective public health strategies. By outlining these expectations, the RFP seeks to attract proposals that will foster sustainable health improvements and community engagement while ensuring compliance with relevant regulations.
    The document serves as an informative attachment regarding an existing base unit related to federal and local requests for proposals (RFPs) and grants. It outlines the current specifications and functionalities of the base unit that is critical for potential bidding agencies to understand the context of the project requirements. Key details include operational capabilities, technical parameters, and integration needs which must be aligned with future project objectives. The attachment emphasizes the importance of compatibility with existing systems and highlights the need for potential contractors to demonstrate thorough knowledge of the unit in their proposals. It aims to facilitate informed bidding processes while ensuring compliance with governmental standards. Understanding this existing base unit is essential for stakeholders involved in the RFP process, guiding them in developing relevant proposals that meet the outlined specifications and expectations.
    This document serves as an informational attachment regarding the existing roof curb within a specified project scope. It outlines the physical characteristics, dimensions, and current condition of the roof curb, which may be relevant for potential contractors or stakeholders involved in the Request for Proposal (RFP) process. The section specifies that the current roof curb's specifications need to be considered when planning any alterations or modifications to the roofing system. Additionally, it emphasizes the importance of understanding existing infrastructure to ensure compliance with building regulations and effective project execution. This attachment is crucial for informing decisions related to maintenance, repairs, or replacements applicable under federal grants or state/local RFPs, facilitating informed bidding and project planning while ensuring adherence to safety and structural integrity standards.
    The document serves as an attachment related to the replacement of the B642 rooftop unit (RTU). It includes a site photo for informational purposes, aimed at aiding stakeholders involved in the project. The main focus is on replacing the existing RTU, indicating a planned upgrade to the heating, ventilation, and air conditioning (HVAC) system. This project likely falls under governmental initiatives to improve infrastructure and operational efficiency in federal or local facilities. The attachment underscores the importance of visual documentation in understanding site conditions and planning for the necessary replacement work, ultimately contributing to enhanced system performance and possibly energy efficiency.
    The document titled "Attachment 1.4 – Existing Ductwork Plan (For Information Only)" outlines the existing ductwork infrastructure for a specified project, intended as an informational reference for stakeholders involved in a federal RFP process. It provides a visual representation and technical details of the ductwork layout, including dimensions, materials used, and any relevant specifications necessary for prospective contractors to understand the current system prior to potential upgrades or modifications. This plan serves to ensure that contractors are aware of the existing conditions, thereby facilitating accurate bidding and planning processes. The document underscores the importance of existing infrastructure assessments in the context of federal grants and proposals, as these evaluations directly impact project feasibility and compliance with regulatory standards.
    The document details the Statement of Work (SOW) for the repair and replacement of the HVAC Roof Top Unit (RTU) at Building 642 on Hancock Field, home of the 174th Attack Wing, New York Air National Guard. The project aims to replace the outdated and inefficient existing RTU, specifically addressing environmental compliance due to the harmful refrigerant R-22. The contractor is responsible for all aspects of the project, including demolition, disposal, installation of a new 15-ton Trane RTU, and ensuring proper connections to the existing building controls system. The project period is set for 180 calendar days, with a focus on quality control and compliance with safety and environmental regulations. Key tasks also involve obtaining necessary permits, hazardous material management, and coordination with base security protocols. The document sets stringent contractor expectations regarding quality assurance, environmental protection measures, and the maintaining of facilities throughout the process to prevent operational disruptions. This project emphasizes the government’s commitment to energy efficiency and environmental stewardship, while also ensuring that work adheres strictly to military protocols and regulations, indicating the seriousness of maintaining governmental standards in facility management.
    The document is a Request for Quotation (RFQ) titled "Repair by Replacement HVAC (RTU), Building 642" for the 174th Attack Wing at Hancock Field, Syracuse, NY. The primary purpose is to solicit quotations for contractors to provide complete labor, materials, tools, and project management required to replace an existing rooftop HVAC unit, deemed obsolete and inefficient, with a new system. The quoted work includes detailed demolition, proper disposal of hazardous materials (such as refrigerant), and installation of an adequately sizedReplacement Unit that complies with current environmental standards. This project has general and specific operational requirements, including the need for certified personnel for installations, project timelines, quality control measures, and compliance with safety regulations. The RFQ outlines responsibilities between the contractor and government representatives, the period of performance (180 days), and critical technical specifications for the new unit. Additional information about materials, environmental considerations, and governmental clauses affecting contractor operations and requirements are included. Overall, this RFQ emphasizes enhancing energy efficiency and compliance with environmental regulations while ensuring the safety and reliability of the HVAC system within the facility.
    The government file outlines various federal and state/local Requests for Proposals (RFPs) and grants. It focuses on the solicitation of statements of qualifications, project proposals, and planning submissions from potential contractors and grant applicants. The document emphasizes the importance of adhering to specific eligibility criteria and submission guidelines, which include timelines and documentation requirements. Previous successful projects and qualifications will be taken into account during the evaluation process to ensure that the selected parties can meet the desired outcomes. Key areas of interest include infrastructure development, environmental sustainability, and community engagement. The file also outlines mandatory compliance with federal regulations, safety standards, and best practices required during project execution. Overall, the document serves as a comprehensive guide for stakeholders involved in the application and bidding processes, aiming to streamline project execution while ensuring that all parties maintain accountability and effectiveness in their proposals. This initiative reflects a commitment to improving governmental operations through competitive bidding and grant processes, facilitating project financing and strategic partnerships with private entities.
    Lifecycle
    Title
    Type
    Remove/Replace HVAC (RTU)
    Currently viewing
    Solicitation
    Similar Opportunities
    Building 210 HVAC Condenser Replacement
    Active
    Dept Of Defense
    The Department of Defense, specifically the Department of the Army, is soliciting proposals for the replacement of a 40-ton HVAC condenser unit at Building 210, Camp Stanley Storage Activity in Boerne, Texas. The contractor will be responsible for the complete removal of the existing unit and installation of a new Trane model or equivalent, including all necessary electrical components and compliance with safety and environmental regulations. This project is part of the government's initiative to maintain operational infrastructure while promoting participation from Historically Underutilized Business Zone (HUBZone) certified small businesses, with a project magnitude estimated between $25,000 and $100,000. Interested bidders must attend a site visit on November 7, 2024, and submit their proposals by November 21, 2024; for further inquiries, they can contact Armando Corral at armando.v.corral.civ@army.mil or 210-253-8688.
    Z1DA--NRM-CONST 528A7-18-725 REPLACE AHUs 2, 7, 11
    Active
    Veterans Affairs, Department Of
    The Department of Veterans Affairs is preparing to issue an invitation for bid (IFB) numbered 36C242-25-B-0001 for the Upgrade Air Handler Equipment project at the Syracuse VA Medical Center. This project involves the replacement of Air Handling Units (AHUs) 02, 07, and 11, along with additional work such as relocating cooling water systems and infection control fans, all while ensuring continuous air supply through temporary equipment. The procurement is specifically set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), requiring bidders to self-perform at least 25% of the work, with an estimated project magnitude between $5 million and $10 million. Interested parties should note that proposals must include a 20% bid bond, and all bidders must be registered in the System for Award Management (SAM) under NAICS code 238220. The contracting period is expected to last 730 days from the notice to proceed, with the project anticipated to commence around November 22, 2024. For further inquiries, contact Sandra L Fisher at sandra.fisher3@va.gov or (315) 425-4694.
    Installation of Subcontractor-Provided 27.5 Ton Electric Heat HVAC RTU
    Active
    Energy, Department Of
    The Department of Energy, specifically Fermilab, is seeking qualified contractors for the installation of a subcontractor-provided 27.5 Ton Electric Heat HVAC Rooftop Unit (RTU) in Batavia, Illinois. The project entails the procurement and installation of the specified HVAC RTU, which includes associated electrical work, ductwork, controls installation and programming, as well as start-up and commissioning activities. This procurement is crucial for enhancing the facility's heating and cooling capabilities, ensuring efficient climate control for research operations. Interested parties are encouraged to attend a Pre-Proposal Meeting and Site Visit on November 5, 2024, and must contact Chris Bushman at cbushman@fnal.gov or 630-840-5501 for further details and to complete necessary access requirements.
    Rental of Temp HVAC
    Active
    Dept Of Defense
    The Department of Defense, specifically the Portsmouth Naval Shipyard, is seeking qualified contractors for the rental of a temporary HVAC system, including necessary support services such as training and maintenance. The objective is to establish a controlled industrial environment by providing continuous tempered air and efficient exhaust systems, which are critical for operational safety and efficiency. Contractors will be required to supply all equipment, labor, and materials, adhering to stringent specifications outlined in the attached Statement of Work, including high-output HVAC units and various support equipment. Interested vendors must submit their proposals by November 6, 2024, at 3:00 PM ET, and can contact David Agea at david.a.agea.civ@us.navy.mil or by phone at 207-994-0614 for further information.
    Z1DA--578-17-012 Replace AHU Air Handling Units in Building 45 (VA-25-00004335)
    Active
    Veterans Affairs, Department Of
    The Department of Veterans Affairs is soliciting bids for the replacement of Air Handling Units (AHUs) in Building 45 at the Edward Hines Jr. VA Hospital in Hines, Illinois, under Project Number 578-17-012. The procurement requires contractors to provide labor, materials, and equipment for the HVAC system replacement and associated renovations, with a performance period of 420 calendar days following the Notice to Proceed. This project is crucial for enhancing the hospital's infrastructure, ensuring improved air quality and operational efficiency for veteran healthcare services. Interested contractors, particularly verified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), must submit their bids by November 14, 2024, and are encouraged to attend a mandatory site visit on October 8, 2024. For further inquiries, contact Andrew Humulock at Andrew.Humulock@va.gov or call 414.384.2000.
    HVAC, Repair and Maintenance for Fort Drum, NY
    Active
    Dept Of Defense
    Presolicitation DEPT OF DEFENSE DEPT OF THE ARMY is seeking multiple vendors for HVAC repair and maintenance service on Fort Drum, NY. This service is used to ensure the proper functioning of refrigeration, air conditioning, and air circulating equipment. The vendors will enter into a Blanket Purchase Agreement (BPA) that will be evaluated annually and may remain in place for up to five years. Interested parties must be registered with the System for Award Management (SAM) under NAICS Code 238220. Please respond via email with intent to participate.
    B1651 HVAC
    Active
    Dept Of Defense
    The Department of Defense, specifically the Air Force's 301st Contracting Flight, is soliciting quotes for a turnkey project to replace the HVAC system at Building 1651 located at Naval Air Station Joint Reserve Base in Fort Worth, Texas. The project involves the brand-name replacement of a 14-ton R-410A VRF Heat Recovery Condensing unit and a six-port Mode Control Unit (MCU), requiring contractors to provide all necessary equipment, labor, and materials while ensuring compatibility with existing systems. This procurement is critical for maintaining operational efficiency and environmental standards within military facilities, with a completion timeline of 90 days post-Notice to Proceed. Interested small businesses must submit their quotes by November 13, 2024, and are encouraged to attend a pre-proposal conference on October 30, 2024, for further clarification on project requirements; for inquiries, contact Todd Benner at todd.benner@us.af.mil or Robert J. Walz at robert.walz.1@us.af.mil.
    Air Handler Unit replacement - Wapato, WA
    Active
    Agriculture, Department Of
    The U.S. Department of Agriculture (USDA) Agricultural Research Service (ARS) is seeking contractors for the replacement of four rooftop air handling units at its facility in Wapato, Washington. The project requires comprehensive services, including the provision of labor, materials, and supervision to ensure the installation of new air handling units that meet current code requirements and the facility's operational needs. This initiative is crucial for maintaining the functionality and efficiency of the mechanical systems essential for the USDA's research operations. Proposals must be submitted electronically by October 15, 2024, with a project budget estimated between $5,000,000 and $10,000,000, and work is expected to commence following a notice to proceed, with a performance period from December 12, 2024, to June 11, 2025. Interested contractors can contact Robert Skipper at robert.skipper@usda.gov or Michael Hassett at michael.hassett@usda.gov for further details.
    Offutt AFB HVAC Control System Upgrade
    Active
    Dept Of Defense
    The Department of Defense, through the 55th Contracting Squadron at Offutt Air Force Base, Nebraska, is seeking potential sources for the upgrade of HVAC control systems, specifically the replacement of outdated Excel 5000 series controllers. The project involves replacing these controllers with compatible Honeywell Tridium N4 products, updating the control system's programming and database, and ensuring compliance with cybersecurity standards while minimizing disruption to facility operations. This upgrade is critical for maintaining the functionality of HVAC systems that support mission-critical operations, as failures can lead to delays and emergency repairs. Interested parties are encouraged to submit their capabilities by 1:00 PM (CST) on November 14, 2024, to the primary contacts, Jose Buenaventura and Austin D. Palrang, via their provided email addresses. Note that this is a sources sought notice for planning purposes only, and no funds are currently available for this effort.
    Replace leaking HVAC condenser coil
    Active
    Homeland Security, Department Of
    The Department of Homeland Security, specifically the U.S. Coast Guard, is seeking qualified contractors to replace a leaking HVAC condenser coil assembly at its facility in Pine Bluff, Arkansas. This procurement is designated as a Total Small Business set-aside under NAICS Code 238220, with an estimated construction cost ranging from $25,000 to $100,000. The selected contractor will be responsible for ensuring minimal disruption to operations while adhering to federal safety and procurement standards, including compliance with the Buy American Act. Quotes are due by 12:00 PM CST on November 5, 2024, and must be submitted electronically to Clarence Henshaw Jr. at clarence.henshawjr@uscg.mil. Interested parties are encouraged to inspect the site and direct any questions to the designated Contracting Officer Representative by the specified deadline.