ContractCombined Synopsis/SolicitationTotal Small Business Set-Aside (FAR 19.5)

USCGC MORRO BAY MDE GENERATOR LOAD BANKING

DEPARTMENT OF HOMELAND SECURITY 70Z08526Q001305
Response Deadline
Dec 10, 2025
Deadline passed
Days Remaining
0
Closed
Set-Aside
Total Small Business Set-Aside (FAR 19.5)
Notice Type
Combined Synopsis/Solicitation

Contract Opportunity Analysis

The Department of Homeland Security, specifically the U.S. Coast Guard, is seeking qualified contractors to provide load banking services for the #2 Main Diesel Engine/Propulsion Generator on the USCGC MORRO BAY, located in Cleveland, Ohio. The contractor will be responsible for supplying all necessary equipment and a qualified technician to perform load banking between December 14 and December 20, 2025, adhering to specific load and timeline parameters while ensuring compliance with safety and contamination prevention measures. This procurement is a total small business set-aside under NAICS Code 336611, with the contract awarded based on the Lowest Price Technically Acceptable (LPTA) criteria. Interested vendors must submit their quotations by 0800 Pacific Time on December 10, 2025, and can direct inquiries to Sean McTague at Sean.P.McTague@uscg.mil or Jason Garris at JASON.A.GARRIS@USCG.MIL.

Classification Codes

NAICS Code
336611
Ship Building and Repairing
PSC Code
2090
MISCELLANEOUS SHIP AND MARINE EQUIPMENT

Solicitation Documents

2 Files
This is a combined synopsis solicitation CGC Morro Bay MDE Generator Load Banking Testing.docx
Word35 KB11/27/2025
AI Summary
This combined synopsis/solicitation, RFQ #70Z08526Q001305, is issued by the United States Coast Guard Surface Force Logistics Center for load banking testing services on the USCGC MORRO BAY's #2 Main Diesel Engine/Propulsion Generator. This is a total small business set-aside with a NAICS Code of 336611 and a small business size standard of 1250. The contract will be a firm-fixed-price award based on the Lowest Price Technically Acceptable (LPTA) using simplified acquisition procedures. Quotations are due by 0800 Pacific Time on December 10, 2025. The contractor will provide all necessary equipment and a qualified technician to perform load banking at the USCGC MORRO BAY in Cleveland, OH, between December 14-20, 2025. Key requirements include adherence to specific load and timeline parameters, protective measures, contamination prevention, a detailed work plan, and registration in the System Award Management (SAM) database.
Morro Bay Load Bank Number Two MDE SOW.doc
Word78 KB11/27/2025
AI Summary
This Scope of Work outlines the requirements for a contractor to provide technical support for load banking the #2 Main Diesel Engine/Propulsion Generator on the U.S. Coast Guard Cutter MORRO BAY in Cleveland, OH. The contractor will perform load banking of the 1000KW, 900VDC, 850 RPMs, 6 Pole Westinghouse generator between December 14-20, 2025. Key requirements include providing a qualified technician experienced in marine generator load banking, furnishing all necessary load banking equipment (including a load bank, wiring, and a portable particle counter), and submitting a detailed work plan. The contractor must adhere to specific load and timeline parameters for engine speeds and generator loads, with Coast Guard personnel witnessing and approving all procedures. The award will be based on the Lowest Price Technically Acceptable (LPTA) offer, and the contractor must be registered in the System for Award Management (SAM) prior to award.

Related Contract Opportunities

Project Timeline

postedOriginal Solicitation PostedNov 26, 2025
deadlineResponse DeadlineDec 10, 2025
expiryArchive DateDec 25, 2025

Agency Information

Department
DEPARTMENT OF HOMELAND SECURITY
Sub-Tier
US COAST GUARD
Office
SFLC PROCUREMENT BRANCH 2(00085)

Point of Contact

Name
McTague, Sean

Place of Performance

Cleveland, Ohio, UNITED STATES

Official Sources