ContractCombined Synopsis/SolicitationTotal Small Business Set-Aside (FAR 19.5)

Safety Railing at UMSB Alexandria, VA

DEPT OF DEFENSE W912HQ26S0027
Response Deadline
May 29, 2026
9 days left
Days Remaining
9
Until deadline
Set-Aside
Total Small Business Set-Aside (FAR 19.5)
Notice Type
Combined Synopsis/Solicitation

Contract Opportunity Analysis

The U.S. Army Corps of Engineers Headquarters, within the Department of the Army, is seeking a small business contractor to install removable safety guardrails at Bldg. 2592A Van Bay for the USACE Mission Support Battalion in Alexandria, Virginia. The work calls for about 100 linear feet of new railing on three sides, with the contractor furnishing all labor, materials, tools, equipment, transportation, and supervision, along with a completed installation, final inspection documentation, warranty information, and manufacturer guidelines. The project requires compliance with OSHA 1910.29 and 1926.502, a 42-inch top rail height, 200-pound strength, galvanized steel or aluminum construction, a powder-coated yellow finish, and security and safety controls including background checks, E-Verify, NCIC-III and TSDB compliance, accident prevention measures, and a quality control program. Offers are to be evaluated on technical capability, past performance, and price, with a firm-fixed-price award under simplified acquisition procedures, and the work must be completed within 90 days of award. Quotes are due by Friday, May 29, 2026, by email, and a site visit is strongly recommended for Thursday, May 21, 2026, with registration due by May 19, 2026 at 5 PM.

Classification Codes

NAICS Code
561210
Facilities Support Services
PSC Code
M1EB
OPERATION OF MAINTENANCE BUILDINGS

Solicitation Documents

3 Files
CSS Questions and Answers.pdf
PDF189 KBMay 20, 2026
AI Summary
The project involves installing approximately 100 linear feet of removable safety railing on three sides. There are no existing rails to be removed. The railing system must comply with Federal OSHA codes, specifically withstanding a 200-pound concentrated load applied to the top rail in any downward or outward direction. To meet this requirement, industrial steel safety rails typically utilize Schedule 40 pipe, which is equivalent to 10-gauge to 12-gauge steel. The removable sections of the railing are specified to be between 5 and 8 feet long. This project likely falls under federal government RFPs for infrastructure or safety upgrades.
SOW Bldg. 2592A Install Safety Railing.pdf
PDF225 KBMay 20, 2026
AI Summary
This Statement of Work (SOW) outlines the requirements for installing 100 linear feet of removable safety guardrails at Bldg.2592A Van Bay, USACE Mission Support Battalion, Alexandria, VA. The project aims to provide fall protection while allowing temporary removal for material handling. The contractor must furnish all labor, materials, tools, equipment, transportation, and supervision. Key technical specifications include compliance with OSHA 1910.29/1926.502, a top rail height of 42 inches (±3 inches), 200 pounds of strength, galvanized steel or aluminum material, and a powder-coated yellow finish. Contractor requirements include site assessment, accurate measurements, maintaining a safe work area, repairing damages, and daily cleanup. Deliverables include the completed installation, a final inspection report confirming compliance, warranty information, and manufacturer guidelines. Strict security requirements, including background checks, E-verify participation, and compliance with NCIC-III and TSDB, are mandated for all contractor personnel. Additionally, comprehensive accident prevention measures, a detailed safety plan, and a quality control program are required. The Contracting Officer Representative (COR) will monitor technical aspects, but cannot alter contract terms or pricing.
CSS_Safety Railing Install.docx
Word49 KBMay 20, 2026
AI Summary
The U.S. Army Corps of Engineers Headquarters issued Solicitation W912HQ26S0027, a combined synopsis/solicitation, for a small business set-aside to install removable safety guardrails at Bldg.2592A Van Bay on USACE Mission Support Battalion. The North American Industrial Classification System (NAICS) code is 561210 with a $47,000,000 size standard. A Firm Fixed Priced (FFP) award will be made using Simplified Acquisition Procedures. Quotes are due by Friday, May 29, 2026, via email. A site visit is strongly recommended for Thursday, May 21, 2026, at 9 AM, with registration required by May 19, 2026, at 5 PM. Offers will be evaluated based on Technical Capability, Past Performance, and Price. The work must be completed within 90 days of contract award. Offerors must be SAM registered, provide a technical work plan (limited to 10 pages), two past performance references, and detailed pricing, including all overhead and G&A.

Related Contract Opportunities

Project Timeline

postedOriginal Solicitation PostedMay 15, 2026
amendedLatest Amendment· Description UpdatedMay 20, 2026
deadlineResponse DeadlineMay 29, 2026
expiryArchive DateJun 13, 2026

Agency Information

Department
DEPT OF DEFENSE
Sub-Tier
DEPT OF THE ARMY
Office
W4LD USA HECSA

Point of Contact

Name
Richard Klein

Place of Performance

Alexandria, Virginia, UNITED STATES

Official Sources