​Consol Tower Sterilizer​

DEPARTMENT OF HEALTH AND HUMAN SERVICES 75N98026Q00400
Response Deadline
Jun 1, 2026
12 days left
Days Remaining
12
Until deadline
Set-Aside
8(a) Sole Source
Notice Type
Combined Synopsis/Solicitation

Contract Opportunity Analysis

The National Institute of Diabetes and Digestive and Kidney Diseases, part of NIH within HHS, is seeking to procure a Consol Tower Sterilizer for Building 5 to replace an aging, high-use autoclave. The requirement is for a dual-chamber, stackable sterilizer with specified chamber dimensions and materials, a hinged manual door, integrated touchscreen controls, programmable cycles, data export capability, and a starter kit. It must fit existing space constraints and include high-vacuum sterilization, water and energy efficiency features, and safety/compliance elements such as ASME U-1, UL, and cUL certification, with performance in Maryland. The purchase is structured as a firm fixed-price order with delivery within 90 days, turnkey installation, de-installation of the old unit, and single lump-sum payment.

Classification Codes

NAICS Code
334516
Analytical Laboratory Instrument Manufacturing
PSC Code
6640
LABORATORY EQUIPMENT AND SUPPLIES

Solicitation Documents

1 Files
SON for Consol Tower Sterilizer.pdf
PDF203 KBMay 19, 2026
AI Summary
The National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) seeks to procure a Consol Tower Sterilizer, specifically a dual-chamber stackable autoclave, for Building 5. This Firm Fixed-Price Purchase Order is driven by the need to replace an aging, high-usage unit, which is over 20 years old and frequently requires repairs. The new sterilizer must be a stackable unit to fit existing space constraints and configuration. Key requirements include specific chamber dimensions and materials, a hinged manual door, integrated control system with a 7-inch touchscreen and 50 programmable cycles, data monitoring capabilities via a thermal printer and USB, a high-vacuum sterilization system, water and energy efficiency features, and safety certifications (ASME U-1, UL, cUL). The order includes delivery within 90 days, turnkey installation (receiving, uncrating, setting, leveling, assembly, utility connections, start-up, user training, debris removal), and de-installation of the old unit. Payment will be a single lump sum.

Related Contract Opportunities

Project Timeline

postedOriginal Solicitation PostedMay 19, 2026
deadlineResponse DeadlineJun 1, 2026
expiryArchive DateJun 1, 2026

Agency Information

Department
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Sub-Tier
NATIONAL INSTITUTES OF HEALTH
Office
NATIONAL INSTITUTES OF HEALTH OLAO

Point of Contact

Name
John Burton

Place of Performance

Maryland, UNITED STATES

Official Sources