This government solicitation (RFQ #36C24526Q0052) from the Department of Veterans Affairs seeks a fully assembled, outdoor hazardous waste storage building for the Louis A. Johnson VAMC in Clarksburg, WV. The contract is a Firm Fixed Price type with a 200-day delivery and offload period. Key technical requirements include specific dimensions (no larger than 112 sq ft), a 4-hour fire rating for walls and 3 hours for the roof, a 393-gallon sump capacity, explosion-proof air conditioning and exhaust systems, LED lighting, ABC dry chemical fire suppression, and R11 insulation. The building must also include shelving, an adjustable vent, a perforated steel ramp, and full-length movable metal grading with spill containment. Vendors must provide a technical plan, product specifications, warranty information, and proof of being an authorized dealer. Evaluation factors include technical compliance, past performance (two relevant references within two years), implementation plan, and price. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses, requires adherence to Buy American—Supplies regulations, and specifies electronic invoice submission.
The Department of Veterans Affairs (VA) is issuing a Combined Synopsis/Solicitation Notice (RFQ #36C24526Q0052) for a Hazardous Waste Storage Building. The VA seeks a vendor to provide and deliver a fully assembled outdoor hazardous storage building that meets VA Statement of Work (SOW) requirements within 200 days of the contract award. This solicitation is set aside for Service-Disabled Veteran-Owned Small Business Concerns (SDVOSBC) and falls under NAICS code 332311 and PSC 8145. Responses are due by October 29, 2025, at 12 PM Eastern Time, New York, USA. The solicitation emphasizes adherence to the SOW for requirements and evaluation factors, and incomplete responses will be considered non-compliant. A key component is the "Buy American Certificate," requiring offerors to certify that end products are domestic, with provisions for listing foreign end products and those containing critical components. The contracting office is the Department of Veterans Affairs, Clarksburg VAMC, and the point of contact is stephanie.henderson3@va.gov.
This document is Amendment 1 to Solicitation 36C24526Q0052 for a Hazardous Waste Storage Unit, issued by the Department of Veterans Affairs, Clarksburg VAMC. The amendment addresses vendor questions and extends the RFQ close date to November 3, 2025, at 12 PM EST. Key clarifications include that the VA does not require fire suppression installation at delivery but will be responsible for anchoring and power hook-up. The vendor will be required to offload the unit, and the VA will provide site pictures. The amendment also includes the "Buy American Certificate" provision (FAR 52.225-2), outlining requirements for domestic end products and critical components.
This government solicitation, 36C24526Q0052, from the Department of Veterans Affairs, Clarksburg VAMC, is for the procurement and destination delivery of a fully assembled outdoor Hazardous Waste Storage Building within 200 days of contract award. The solicitation outlines specific technical requirements, including size, fire rating, sump capacity, electrical components, explosion-proof features, shelving, and ramp specifications. It is a total set-aside for Certified Service-Disabled Veteran-Owned Small Businesses. Evaluation factors include technical compliance, past performance (two relevant references within the last two years), implementation plan (including a qualified certified installer for fire suppression activation within 10 days of delivery), and price. Vendors must submit quotes in PDF/XLS format via email to Stephanie.Henderson3@va.gov by the due date, listing the RFQ number in the subject line. The contract type is Firm Fixed Price, and payment will be made electronically upon acceptance of goods.
The document outlines the requirements for an outdoor hazardous waste storage building, detailing specific features such as dimensions no larger than 112 square feet, a 393-gallon sump capacity, and R11 insulation. Key safety specifications include an explosion-proof exhaust system, emergency shut-off, LED lighting, and a 4-hour fire-rated structure. Electrical requirements specify a 100A load center. The building must also include an explosion-proof air conditioner, an ABC dry chemical fire suppression system, 14-inch shelves, a perforated steel ramp, and movable metal grading with spill containment. Delivery to a VA site pad is required within 200 days. The vendor must provide a manufacturer letter of authorization, destination delivery date, and details on their solution, including model name/number, place of manufacture, and price.
This government solicitation outlines requirements for an outdoor hazardous waste storage building. Key specifications include a maximum size of 112 square feet, a 393-gallon sump capacity, R11 insulation, and a grounding kit. The building must feature an explosion-proof exhaust system with an emergency shut-off, LED lighting, and adjustable vents, all compliant with Class 1 Division 2 standards. It requires a 60"W x 80"H double staff entry door and must be 4-hour fire-rated for walls and 3-hour fire-rated for the roof, both FM approved. Electrical components include a 100A main breaker load center and an explosion-proof air conditioner (15,700 Btu). A dry chemical fire suppression system with an audible alarm is mandatory, along with 14"W shelves, a 52"W x 72"L perforated steel ramp, and full-length movable metal grading with spill containment. Delivery is required within 200 days to a loading dock. Vendors must provide the model name/number, place of manufacture, and price for their solution.